- safety category 3
- two safety circuits
- four OSE-inputs
- positively driven safety-relays
- signal contact with pulse function
- power-/function-display-LEDs
The AOS 6000 was developed as a universally applicable safety processing unit for our SIGNAL and LOW-POWER-SIGNAL series as well as other common optoelectronic safety edges. The AOS 6000 can also be used as a safety processing unit with our pull-in protection series TWIN-PRO.
The AOS 6230 offers 2 active safety circuits and the possibility to monitor 4 optoelectronic safety edges in accordance with EN13849-1 Category 3 (DE). A typical application including the AOS 6230 would be the usage of 3 pull in protections "TWIN-PRO" on one safety circuit and the "SIGNAL" safety edge on on the second circuit.
The AOS 6000 can easily be integrated into the existing control unit as an additional safety function.
Operating voltage:
230 VAC
Ordering details
AOS 6230
Operating voltage
230 VAC
64315427
For further technical details please refer to the following datasheet: